Shopping security
A ball valve is used as a shut-off valve to shut off the flow of the working medium in pipelines.
PA-DA-x double-acting pneumatic actuators use two ports to supply the control medium and create movement in both directions, both to open and close the valve. One port is used to move the piston in one direction and the other port is used to move the piston in the opposite direction.
The MON worm gear manual quarter-turn doubleturn actuator with reduction gearbox allows manual adjustment of the required positioning of the shut-off valve by a quarter turn, acting as an alternative to pneumatic, electric or hydraulic quarter-turn actuators.
The limit switch unit is designed for visual and electrical signalling of the end positions of the shut-off valve, valve, tap or disc gate. It is mounted on top of the pneumatic actuator surface and is connected to the actuator shaft in DIN standard. The sealed box usually contains two sensors that monitor the position of the actuator shaft and signalise in extreme positions. OMRON microswitches, inductive sensors or reed switches are used as sensors.
Pneumatic distributor is used to change the direction, start, stop the compressed air flow in the pneumatic system depending on the external control action.
| Characteristic | Meaning |
| Type of flow section | full bore |
| Diameter | 15-100 mm |
| Nominal pressure | 10 bar |
| Working medium temperature | from 0 to +45°C |
| Application | Water Supply |
| Operating environment | Liquids, Air and Gases |
| Connection type | adhesive, with a detachable coupling connection |
| Control type | under the drive |
| Sealing class | A |
| Manufacturer's country | China |
| Warranty | 12 months |

| Model | DN15 | DN20 | DN25 | DN32 | DN40 | DN50 | DN65 | DN80 | DN100 |
| D, mm | 56 | 65 | 75.5 | 86.5 | 101 | 121.5 | 153 | 175 | 194 |
| d, mm | 15 | 20 | 25 | 32 | 40 | 50 | 63 | 75 | 90 |
| d1, mm | 20.3 | 25.3 | 32.3 | 40.4 | 50.4 | 63.4 | 75.5 | 90.5 | 110.5 |
| d2, mm | 20 | 25 | 32 | 40 | 50 | 63 | 75 | 90 | 110.1 |
| L, mm | 123.5 | 137 | 148 | 165 | 176 | 197 | 279 | 307 | 354 |
| L1, mm | 23 | 26 | 29 | 32.5 | 35.5 | 38.5 | 65 | 70 | 84 |
| L2, mm | 67 | 74 | 77 | 88 | 93 | 105 | 134 | 148 | 157.5 |
| H1, mm | 66 | 77.5 | 89.5 | 103 | 116.5 | 138 | 171 | 194 | 220 |
| H2, mm | 27.5 | 32 | 37.5 | 43 | 50 | 60 | 76 | 88 | 99.5 |
| H3, mm | 8 | 8 | 8 | 12 | 12 | 13 | 16 | 16 | 17.5 |
| SxS, mm | 9x9 | 9x9 | 9x9 | 11x11 | 11x11 | 11x11 | 14x14 | 14x14 | 14x14 |

| № | Part Name | Material |
|---|---|---|
| 1 | Body | UPVC |
| 2 | Ball | UPVC |
| 3/4/ 5/6 |
O-ring seals | EPDM |
| 7 | Rod | Stainless steel AISI 304 |

| Characteristic | Meaning |
| Pneumatic drive type | double acting |
| Nominal pressure | 12 bar |
| Working pressure | 2-8 bar |
| Ambient temperature | from -20 to +80 °C |
| Swivel angle | 0-90° |
| Position indicator | open / closed |
| Working environment | filtered compressed air |
| Swivel angle adjustment | ±5% |
| Top and air connection standard | NAMUR |

| Model | A, mm |
B, mm |
C, mm |
D, mm |
E, mm |
F, mm |
G, mm |
H, mm |
| DA-052 | 30 | 41,5 | 65,5 | 72 | 92 | 65 | 30 | 80 |
| DA-065 | 36 | 47 | 81 | 88 | 108 | 72 | 30 | 80 |
| DA-083 | 46 | 57 | 98,5 | 108,7 | 128,7 | 92 | 30 | 80 |
| DA-105 | 57,5 | 64 | 122,5 | 133 | 153 | 109,5 | 30 | 80 |
| DA-130 | 67,5 | 74,5 | 145,5 | 155 | 185 | 127,5 | 30 | 130 |
| DA-140 | 75 | 77 | 161 | 172 | 202 | 137,5 | 30 | 130 |
| DA-160 | 87 | 87 | 184 | 197 | 227 | 159 | 30 | 130 |
| DA-210 | 113 | 113 | 235,5 | 255 | 285 | 210 | 30 | 130 |
| DA-270 | 147 | 147 | 299 | 326 | 356 | 273 | 30 | 130 |
| DA-300 | 162 | 174 | 330 | 350 | 380 | 312 | 30 | 130 |
| DA-350 | 190 | 195 | 483 | 410 | 440 | 365 | 30 | 130 |
| Model | I, mm |
J, mm |
M, mm |
N, mm |
Z, mm |
d, mm |
K | L |
| DA-052 | 36 | 50 | 11x11 | 14 | 147 | 40 | M5x8 | M6x10 |
| DA-065 | 50 | 70 | 14x14 | 18 | 168 | 40 | M6x10 | M8x13 |
| DA-083 | 50 | 70 | 17x17 | 21 | 204 | 40 | M6x10 | M8x13 |
| DA-105 | 70 | 102 | 22x22 | 26 | 268 | 40 | M8x13 | M10x16 |
| DA-130 | 70 | 102 | 22x22 | 26 | 301 | 55 | M8x13 | M10x16 |
| DA-140 | 102 | 125 | 27x27 | 31 | 390 | 55 | M10x16 | M12x20 |
| DA-160 | 102 | 125 | 27x27 | 31 | 458 | 55 | M10x16 | M12x20 |
| DA-210 | - | 140 | 36x36 | 40 | 532 | 80 | - | M16x25 |
| DA-270 | - | 165 | 46x46 | 50 | 718 | 80 | - | M20x25 |
| DA-300 | - | 165 | 46x46 | 50 | 760 | 80 | - | M20x25 |
| DA-350 | 165 | 254 | 46x46 | 50 | 920 | 80 | M20x25 | 8xM16x25 |

| Characteristic | Meaning |
| Terminal Block | 8 cells 0.08-2.6mm2 |
| Voltage | 12V, 24V, 38V, 48V, 110V, 220V, 250V |
| Indicator Position | CLOSED: red, OPEN: green |
| Ambient temperature | from -40 to +80 °C |
| Cable Entry Thread | 2 x NPT1/2" |
| Sensor | 2 SPDT electromechanical microswitches OMRON V151-1C25 |
| External Coating | polyester coating (black) |
| Shaft | Standard (17mm) |
| Protection class | IP65 |

| Depth, mm | 112 |
| Height, mm | 77 |
| Width, mm | 88 |

| Design | Spool-type |
| Test pressure (body strength test. Not for operation!), bar | 10 |
| Working pressure (recommended range for normal operation), bar | 1.5 ÷ 8 |
| Valve type | 5/2 five-port, two-position |
| Working medium | purified air (40 µm filter fineness) |
| Operating temperature, °C | 0 to +60 |
| Actuation frequency | 5 cycles per second |
| Manual override | yes |
| Protection rating/insulation class | IP65/F |
| Connection to pneumatic actuator | NAMUR-compliant mounting surface (VDI/VDE3845) |
| Body material | anodized aluminum |
| Effective cross-sectional area, mm2 | 25 (Cv = 1.4) |
| Exhaust port dimensions (vent to atmosphere) | 2 - PT1/4” |
| Air inlet port size (to pneumatic valve) | G1/4” |
| Air outlet port size (to pneumatic actuator) | 2 x Ø19.2 mm |
| Response time, sec | 0.05 |
| Supply voltage, V | 220AC/24DC |
| Coil power | 220VAC – 5.5 VA/24VDC – 4.8 W |
| Weight, kg | 0.35 |
| Average service life, cycles | 10,000,000 |
| A | C | D | E | F | G | H | I | K | L | J | N | M |
| mm | ||||||||||||
| 40 | 24 | 28 | 32 | 40 | 21,5 | 69 | 45 | 17,5 | 135 | 29,3 | 40 | 27 |

Sketch of the dimensions of the pneumatic distributor 4M310-08 NAMUR
| № | Part Name | Material |
| 1 | Connector | Engineering plastic |
| 2 | Nut | POM + carbon steel |
| 3 | Coil | Copper |
| 4 | Control Elements | — |
| 5 | Plate | Carbon steel |
| 6 | Piston | POM |
| 7 | Control Valve Seat | Engineering plastic |
| 8 | Valve Body | Aluminum alloy |
| 9 | Spool | Aluminum alloy |
| 10 | O-Ring Seal | HNBR |
| 11 | Rear Cover | Engineering plastic |
| 12 | Filter | Synthetic material |
| 13 | Piston | POM |
| 14 | Spring | Stainless steel |
| 15 | Manual Override | Engineering plastic |
| 16 | Rear Seat | Aluminum alloy |
| 17 | Spring Seat | Aluminum alloy |
| 18 | Type C Towing Shackle | 65Mn |

Sketch of the dimensions of the pneumatic distributor 4M310-08 NAMUR
| Characteristic | Meaning |
| Operating mode | repetitive-short-term, reversible |
| Application | water supply, heating, fire extinguishing, heating stations |
| Place of installation | between pneumatic actuator and ball valve or gate valve |
| Operating temperature | from -20 to +80 °C |
| Shaft angle | 90±5° |
| Mounting | horizontal/vertical |
| Working environment | filtered compressed air or non-aggressive gases, oils |
| Protection class | IP67 |

| Model | MON1- 250- T26-ISO |
MON2- |
Ships within 48 hours · Estimated delivery Jun 26 - Jul 1
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order