Shopping security
| Rated Inverter Power | 6500VA/6500W |
| AC Voltage Regulation | 120VAC ± 5% |
| Surge Power | 15000VA |
| Efficiency (Peak) | 90% ~ 93% |
| Transfer Time | 15 ms (For Personal Computers), 20 ms (For Home Appliances) |
| Waveform | Pure Sine Wave |
| No Load Power Consumption | <70W |
| Optional DC Voltage | 12 VDC ± 5%, 100W |
| Dual Outputs | Yes |
| Voltage | 120 VAC |
| Selectable Voltage Range | 90-140 VAC (For PC), 80-140 VAC (Home Appliances) |
| Frequency Range | 50 Hz/60 Hz (Auto Sensing) |
| Battery Voltage | 48 VDC |
| Floating Charge Voltage | 54 VDC |
| Overcharge Protection | 66 VDC |
| Solar Charger Type | MPPT |
| Maximum PV Array Power | 8000W (4000W x 2) |
| MPPT Operating Voltage | 90 ~ 230 VDC |
| Max PV Array Open Circuit | 250 VDC |
| Maximum Solar Charge Current | 120A |
| Maximum AC Charge Current | 120A |
| Maximum Charge Current | 120A |
| Dimension (D x W x H) | 5.8 x 17.0 x 21.8 in |
| Net Weight | 40.6 lb |
| Communication Interface | USB/RS232/RS485/Wi-Fi/Dry-contact |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -15°C to 60°C |
| Compliance Safety | UL |
| Parallel Capability | Yes, 6 units |
| Nominal Voltage | 51.2V |
| Nominal Capacity (at .5C, 77°F) | 100Ah |
| Minimum Capacity (at .5C, 77°F) | 99.5Ah |
| Nominal Capacity | 5120Wh |
| Charging Voltage | 57.6V |
| Discharging Cutoff Voltage | 44.8V |
| Maximum Charging Current | 100A |
| Continuous Charge Current | 100A |
| Maximum Discharge Current | 100A |
| Battery Dimensions | 17.7″L x 17.8″W x 5.2″H |
| Weight | 99.2 lb |
| Operation Voltage | 43.2~58.4V |
| Maximum Charging Current | 100A |
| Maximum Discharging Current | 100A |
| Maximum Charge Voltage (CC/CV) | 57.6V |
| Overcharge Protection Voltage (Battery) | 58.4V |
| Overcharge Protection Release Voltage (Battery) | 54V |
| Over Discharge Protection Voltage (Battery) | 43.2V |
| Over Discharge Protection Release Voltage (Battery) | 47.2V |
| Over Discharge Primary Charge Overcurrent Protection | 110A |
| First Stage Charge Over Current Delay | 1s |
| Primary Discharge Overcurrent Protection Value | 110A |
| Primary Discharge Overcurrent Protection Delay | 1s |
| Secondary Discharge Overcurrent Protection Value | 150A |
| Primary Discharge Overcurrent Protection Delay | 500ms |
| Charge Temperature | 0.1C@(0℃~10℃); 0.2C@(10℃~20℃); 0.5C@(20℃~25℃); 1C@(25℃~45℃); 0.3C@(45℃~55℃); 0.2C@(55℃~60℃); |
| Discharge Temperature | -20℃~65℃ (The surface temperature of the cell should not exceed 65℃) |
| Storage Temperature | -20℃~45℃ 90%RH Max(1 month); 0℃~35℃ 90RH Max(6 Months) |
| Recommended Storage Temperature | 0℃~35℃ 85%RH Max (The battery life would be reduced if battery is stored in high temperature) |
| Communication Ports | RS485/RS232/CAN |
| Warranty | 10 Years Manufacturer Defect |
Rich Solar 6500 Inverter User Manual
Rich Solar 6500 Inverter Certification
Rich Solar 6500 Inverter Specifications
Alpha 5 Pro | 51.2V 100Ah Server Rack Lithium Iron Phosphate Battery Specification
Alpha 5 Pro | 51.2V 100Ah Server Rack Lithium Iron Phosphate Battery User Manual
Ships within 48 hours · Estimated delivery Jun 22 - Jun 27
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order