20% OFF shipping at tug-ottendorf-okrilla.de on orders over $79 + up to 10% OFF products
tug-ottendorf-okrilla.de
home > FC-BSN-1608 Honeywell NAMUR Converter | New & Original Stock > FC-BSN-1608 Honeywell NAMUR Converter | New & Original Stock
download picture
FC-BSN-1608 Honeywell NAMUR Converter | New & Original StockHoneywell FC BSN 1608 Safety Manager Series The Honeywell FC BSN 1608, also cataloged as the FC BSN 1608 Fail Safe NAMUR Sensor Converter Module, operates as a dedicated hardware component for NAMUR proximity sensor signal processing within Honeywell Safety Manager platforms. Hardware Specifications Parameter Specification Model FC BSN 1608 Brand Honeywell Origin United States Weight 0. 63 kg (Net Weight) Dimensions 14. 8 cm x 7. 0 cm x 26. 9 cm
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Honeywell FC-BSN-1608 Safety Manager Series

The Honeywell FC-BSN-1608, also cataloged as the FC-BSN-1608 Fail-Safe NAMUR Sensor Converter Module, operates as a dedicated hardware component for NAMUR proximity sensor signal processing within Honeywell Safety Manager platforms.

Hardware Specifications

Parameter Specification
Model FC-BSN-1608
Brand Honeywell
Origin United States
Weight 0.63 kg (Net Weight)
Dimensions 14.8 cm x 7.0 cm x 26.9 cm
Operating Temp -40 deg C to 70 deg C (-40 deg F to 158 deg F)
Power Consumption Sourced via Safety Manager backplane
Input Channels 16 independent channels
Standard Compliance NAMUR EN 60947-5-6
Input Signal Range 1.2 mA to 2.1 mA typical switching thresholds
Short Circuit Threshold > 6.0 mA
Open Circuit Threshold < 0.35 mA
Isolation Barrier Integrated galvanic isolation
Diagnostics Layer Per-channel wire-fault loop monitoring

Galvanic Isolation & NAMUR Sensor Loop Diagnostics

The converter module hosts 16 independent instrumentation channels designed to monitor input currents from proximity switches conforming to EN 60947-5-6 standards. Internal comparator networks map field impedance variations against specified switching limits, using galvanic isolation to separate incoming field transients from the primary safety logic solver backplane.

The hardware subassembly executes real-time loop diagnostics by continuously tracking boundary current zones. Field currents dropping below 0.35 mA register as an open-circuit fault, while line currents exceeding 6.0 mA trip short-circuit hardware indicators. These diagnostic values are read directly by the internal processor to inhibit faulted channels inside the voting matrix, preventing indeterminate states from driving active logic outputs.

Frequently Asked Questions

Q: Does the FC-BSN-1608 support on-line hot-swap replacement within an active Safety Manager chassis? A: Yes. The mechanical interface is keyed for online insertion and removal under backplane electrical load. However, extraction of this module instantly breaks the 16 active NAMUR sensor loops, driving associated application variables to their configured fail-safe states in the control logic.

Q: Is external power required to drive the field-side NAMUR proximity sensors? A: No. The module isolates and steps down internal backplane power to provide the necessary excitation voltage directly to the 16 field channels, eliminating the need for external loop power distribution terminals.

Q: How does the module handle short-duration electrical noise on the sensor line to prevent false wire-fault alarms? A: The hardware employs built-in analog filters combined with firmware-level debouncing on each channel. Transient spikes that do not persist past the hardware evaluation window are suppressed, ensuring only sustained line disruptions register as open or short-circuit faults.

Field Installation Guidelines

  • Chassis Slot Alignment: Insert the module into the designated slot of the Safety Manager chassis. Engage the top and bottom extraction levers to seat the card edges into the backplane, and tighten the retaining screws to guarantee continuous electrical bonding.
  • Shield Termination Protocol: Route all NAMUR sensor cables using twisted-pair shielded instrumentation wiring. Terminate the outer shields exclusively at the designated enclosure ground bar, ensuring the drain wires are insulated at the field instrument side to stop common-mode current loops.
  • Conduit Routing Constraints: Maintain physical separation between the low-voltage NAMUR sensor input conduits and high-power AC distribution or inductive motor control wires to minimize electrical noise injection into the diagnostic detection circuitry.

FC-BSN-1608 Honeywell NAMUR Converter | New & Original Stock

Item no : 40847356904
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 5 - Jul 10

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches