home > 24VDC 16-Channel Fail-Safe Output Card | FC-SDO-1624 > 24VDC 16-Channel Fail-Safe Output Card | FC-SDO-1624
download picture
24VDC 16-Channel Fail-Safe Output Card | FC-SDO-1624Product Overview The Honeywell FC SDO 1624 provides high density, fail safe switching for critical final elements within the Honeywell Fail Safe Control (FSC) and Safety Manager ecosystems. This module features 16 independent 24 VDC channels, allowing the safety controller to manage solenoid valves, emergency shutdown (ESD) relays, and signaling devices from a single rack slot. It converts safety logic into physical actions while maintaining rigorous
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Honeywell FC-SDO-1624 provides high-density, fail-safe switching for critical final elements within the Honeywell Fail-Safe Control (FSC) and Safety Manager ecosystems. This module features 16 independent 24 VDC channels, allowing the safety controller to manage solenoid valves, emergency shutdown (ESD) relays, and signaling devices from a single rack slot. It converts safety logic into physical actions while maintaining rigorous SIL 3 integrity. We provide this module as 100% Brand New and Original, ensuring your safety-instrumented system (SIS) operates with genuine, factory-certified hardware.

Technical Specifications

The FC-SDO-1624 utilizes a robust electrical architecture to ensure rapid response and localized fault containment.

Feature Specification Details
Number of Channels 16 Independent Output Channels
Output Type Fail-Safe Digital Output (DO)
Input Voltage 24 VDC (Nominal)
Current per Channel Up to 1 A (Load dependent)
Safety Integrity Level SIL 3 Capable (IEC 61508)
Response Time High-speed safety execution
Diagnostics Short circuit, open circuit, and watchdog monitoring
Operating Temperature –40 °C to +70 °C
Isolation Channel-to-system galvanic isolation
Installation Chassis-mounted in FSC/Safety Manager racks

Engineering Advantages

  • Optimized Cabinet Footprint: By integrating 16 channels into a single module, the FC-SDO-1624 reduces the number of I/O cards required for large-scale operations. This high-density design lowers overall hardware costs and simplifies cabinet wiring in space-constrained offshore or refinery control rooms.

  • Proactive Fault Detection: The onboard diagnostic suite continuously identifies field-side anomalies such as short circuits and line breakages (open circuits). This ensures that the safety loop remains functional and ready to execute a shutdown command when demanded by the process.

  • Fail-to-Safe Hardware Watchdog: An integrated hardware watchdog monitors the internal processor's health. If the module detects an internal logic discrepancy or processor failure, it automatically de-energizes all outputs to their predetermined safe state, preventing uncontrolled process scenarios.

  • Extreme Environment Durability: Rated for an operating range of –40 °C to +70 °C, this module thrives in unconditioned industrial cabinets. It resists the thermal stress associated with outdoor enclosures in extreme climates, ensuring long-term hardware reliability.

FAQs

  • Can the FC-SDO-1624 drive high-current solenoid valves?

    Yes. Each of the 16 channels supports up to 1 A, which covers most standard industrial solenoid valves and ESD relays. However, always calculate the total rack power budget to ensure the power supply supports the simultaneous activation of multiple loads.

  • How does the module signal a field-side fault to the controller?

    The module identifies faults through its diagnostic circuitry and communicates these status bits back to the Safety Manager controller. You can then view these alerts via the system software for rapid troubleshooting.

  • Does this module support line monitoring for fire and gas applications?

    The FC-SDO-1624 includes built-in diagnostics for open and short circuits, which are essential for monitoring the integrity of safety loops in fire, gas, and emergency shutdown systems.

  • Is this a refurbished or surplus unit?

    No. We guarantee that every FC-SDO-1624 is 100% Brand New and original Honeywell stock. Each module ships in its original factory packaging with a full 12-month warranty.

24VDC 16-Channel Fail-Safe Output Card | FC-SDO-1624

Item no : 55387545805
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 5 - Jul 10

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches