The Wilkins 112-500XLHR is a high-performance water pressure reducing valve with an integral by-pass check valve, designed for industrial and commercial water systems requiring reliable pressure control and thermal expansion protection.
Key Specifications:
Other Related Variants:
Materials:
Local codes shall govern installation requirements. The assembly shall be mounted in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. The assembly shall be installed with sufficient side clearance for testing and maintenance. The Model 500XL may be installed in any position. If installed in a pit, vault, or inside application, specify the "SC" sealed cage option. Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 3 to 1 (i.e.: 150 psi inlet reduced to 50 psi outlet). Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting.
ASSE 1003; cUPC; CSA B356; City of Los Angeles; NSF/ANSI/CAN 61; NSF/ANSI/CAN 372
Features & Benefits:
Q: What is the pressure range difference between the 112-500XLHR and standard 112-500XL models?
A: The Wilkins 112-500XLHR features the HR (High Range) option with a 75 psi to 125 psi spring range factory set at 85 psi, while the standard model has a 25 psi to 75 psi range factory set at 50 psi.
Q: Can the 112-500XLHR be installed vertically or horizontally?
A: Yes, the Zurn 112-500XLHR may be installed in any position. However, if installed in a pit, vault, or inside application, the "SC" sealed cage option should be specified for optimal performance.
Q: What is the maximum pressure reduction ratio recommended for this valve?
A: Multiple installations are recommended where the desired pressure reduction exceeds a 3:1 ratio (for example, reducing from 150 psi inlet to 50 psi outlet). A downstream pressure gauge must be used when adjusting the valve.
NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.
"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us
Ships within 48 hours · Estimated delivery Jul 6 - Jul 11
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order