Shopping security
A fantastic pack for all of your Beast Mode needs!
The NEW Fieldpiece VPX7INT high-efficiency Vacuum Pump with RunQuick™ Oil Change System - No Fuss - No Mess

| Flow Rate | 10 CFM (283 l/m) |
| Oil Capacity | 8oz (237mL) |
| Oil Compatibility | Fieldpiece Vacuum Pump Oil (Highly refined and optimized for proper sealing and lubrication) |
| Fieldpiece part numbers | OIL8X3, OIL32, OIL128 |
| Oil Backlight | Blue LED |
| Oil Drain | Ball valve |
| Port Sizes | (1) 1/4”, (2) 3/8”, (1) 1/2” |
| Compressor | Rotary vane, two stage |
| Motor | 3/4 HP Brushless DC |
| RPM | 2500 |
| Power Source | 240 VAC @ 50 Hz 1 phase |
| Nominal Current Draw | 6.0 AAC |
| Ultimate Vacuum at Input Ports | 15 microns |
| Operating Environment | -1.1°C to 50°C |
| Dimensions | 201 mm x 296 mm x 406 mm |
| Weight | 11.1 kg |
Refrigerant Recycling has never been easier or faster with the MR45INT Recovery Machine

Dual cylinder compressor with long life and low friction with ceramic lined cylinders
| Display | 2 x 10000 count LCD with status messages |
| Backlight | Blue color |
| Measurement rate | 3.3 times per second, nominal |
| Input Port Pressure Sensor Range | -30” Hg to 600 psig |
| Output Port Pressure Sensor Range | -30” Hg to 600 psig |
| High Pressure Cutoff | 558 psig, nominal |
| Resolution and Units | 1 psig (1” Hg), 0.05 bar (2 cmHg), 0.01 Mpa (2 cmHg), 5 Kpa (2 cmHg) |
| Pressure Sensor Accuracy | ± 0.5 “ Hg (Vacuum) ± (0.6% of reading +2 psig) |
| Final Recovery Vacuum | 14.9” Hg |
| Compressor | Twin cylinder reciprocating (oil-less) |
| DC Motor | 1 HP (variable smart speed) |
| Power Source | 220 - 240 VAC @ 50 Hz 1 phase |
| Max Current Draw | 7.0 Amp |
| Valve | Single dual-route ball valve |
| Input Port Filtration | 9 mm mesh screen, stainless |
| Dimensions | 376 mm x 250 mm x 344 mm |
| Weight | 10 Kgs |
| Operating Environment | 32°F to 122°F (0°C to 50°C) |
| Storage Environment | -4°F to 140°F (-20°C to 60°C) |
| Approved Refrigerants | R12, R12345YF, R134A, R22, R32, R401A (MP39), R401B, R401C, R402A, R402B, R404A, R407A, R407B, R407C, R407D, R408A, R409A, R410A, R412A, R500, R502, R507, R509 |
The newly designed Fieldpiece Manifolds are stronger and more robust than ever before!

Data Logging
Tightness Test Built-in Feature
Customisable Menu
Receives Wireless Measurements
Add Job Link Tools to your arsenal and get live readings directly on the SMAN manifold screen from the Job Link Psychrometers (JL3RH), Job Link Pipe Clamps (JL3PC), and SRS3 Refrigerant Scale.
Place pipe clamps in the perfect location. Monitor and record live refrigerant usage for precise recovery, charging, and documentation.
View live air measurements and calculations while making adjustments.
Increase Professionalism with Job Link® System App
Streamline and simplify your call even further with the Job Link System App. See your measurements up to 100 metres away on your mobile device.
Document your work and provide professional reports, including refrigerant weight usage, by simply connecting to the Job Link System app. Helps to reduce call-backs and increase profits.
| Display | LCD (5 inches diagonal) |
| Backlight | Blue (adjustable duration) |
| Low Battery Indication | Displayed when the battery voltage drops below the operating level |
| Over Range Display | OL for pressure, – – – – for temperature |
| Auto Power Off | 30 minutes of inactivity (adjustable) |
| Maximum Manifold Pressure | 800 Psig (5500 kPa) |
| Battery Type | 6 x AA alkaline |
| Battery Life | 350 hours typical (without vacuum, backlight, and wireless) |
| Radio Frequency | 2.4 GHz |
| Wireless Range | 305 meters line of sight – distance decreases through obstructions |
| Data Port | Micro USB (for extracting data logs or updating firmware) |
| Operating Environment | 0°C to 50°C at <75% RH |
| Storage Environment | -20°C to 60°C at <80% RH (with battery removed) |
| Temperature Coefficient | 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C) |
| Weight | 1.83 kg |
| Water Resistant | Designed to IP54 |
Infrared Refrigerant Leak Detector for HVACR - Superior Sensitivity in a Rugged Design for HVACR

| Sensor Type | Infrared (IR) |
| Sensor Life | 10 years typical |
| Sensitivity Levels | High, medium, low, turbo (selectable) |
| Maximum Sensitivity | 0.03 oz/yr (1g/a), stationary; 0.1 oz/yr (3g/a), in motion |
| Display Type | LCD (backlit for indoor use) |
| Detection Feedback | Red tip LED, LCD bar graph, LCD digits, beeper |
| Refrigerants | Detects CFC, HFC, HCFC, HFO and blends and doesn’t trigger on oil or soap bubbles |
| Response Time | <1 seconds typical |
| Recovery Time | <5 seconds typical |
| Body Type | Compact, rugged overmolded |
| Battery Type | 3.7 VDC (nominal) 2600mAh, non-replaceable |
| Charge Time | 6 hours typical with included charger. |
| Battery Life | 10 hours typical, backlight off |
| Auto Power Off | 10 minutes without detection or button press |
| Operating Environment | 32°F to 104°F (0°C to 40°C); < 75% RH (non-condensing) |
| Storage Temperature | -4°F to 140°F (-20°C to 60°C); < 80% RH |
| Weight | 14 oz (400g) |
| Water Resistance | Designed to IP54 |
The NEW MG44 Micron Gauge Impact and Weather Resistant designed for the field

| Minimum Device Requirement | BLE 4.0 devices running: iOS® 7.0 or Android™ 5.0 (Latest compatibility at www.fieldpiece.com) |
| Connector type | 1/4” SAE male fitting |
| Accuracy | ±(5% of reading + 5 microns) at 77°F (25°C), 50 to 1000 microns |
| Range and Units | 50 to 25000 microns of mercury (English), 6 to 3333 Pascals (Metric), 0.06 to 33.33 mBar (Metric), 50 to 25000 mTorr (Metric), 0.05 to 25 Torr (Metric, equivalent to mmHg) |
| Best Resolution | 1 micron of mercury (below 2000 microns), 1 Pascal (below 250 Pascals), 0.001 mBar (below 2.5 mBar), 1 mTorr (below 2000 mTorr), 0.001 Torr (below 2.5 Torr, equivalent to mmHg) |
| Battery Type | 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6 |
| Battery Life | 40 hours typical alkaline |
| Auto Power Off | 15 minutes default (APO adjustable) |
| Wireless Range | 1000 feet (305 meters) line of sight. Obstructions affect distance. |
| Radio Frequency | 2.4 GHz |
| Water Resistence | IP55 |
| Operating Environment | 14°F to 122°F (-10°C to 50°C) at <75% RH |
| Storage Temperature | -4°F to 140°F (-20°C to 60°C) at <80% RH (with batteries removed) |
| Weight | 0.66 lbs (300 g) |
The New Heavyweight Champion

Please Note: Gas bottle in the image not included, for demonstration purposes only.
| Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity | |
| Over range | “OL” is displayed |
| Maximum load | 252 lbs (114 kg) |
| Max tank base diameter | 13 inches (33 cm) |
| Auto power off | 30 minutes of inactivity (no change in weight or buttons pressed), (APO can be disabled) |
| Backlight | Blue, turns off in 2 minutes if no buttons are pressed |
| Accuracy | ±0.03%rdg + 0.25 oz (10 g), 0 to 66 lbs (0 to 30 kg) ±0.05%rdg + 0.25 oz (10 g), 66 to 252 lbs (30 to 114 kg) |
| Resolution and Units | lb oz (0.25 oz), lb (0.1 lb), oz (0.3 oz), kg g (10 g), kg (0.1 kg), g (10 g) |
| Temperature coefficient | 0.1 x (specified accuracy) per °F |
| Wireless Range | 1000 feet (305 meters) line of sight |
| Radio Frequency | 2.4 GHz |
| Battery Type | Remote Display: 1 x 9V, NEDA 1604, JIS 006P, IEC 6F22 Platform: 6 x AA, NEDA 15A, JIS UM3, IEC LR6 |
| Battery Life | Remote Display: 80 hours typical alkaline (backlight off) Platform: 200 hours typical alkaline |
| Remote Display | 80 hours typical alkaline (without backlight) |
| Platform | 200 hours typical alkaline |
| Operating environment | 32°F to 122°F (0°C to 50°C) at <75% RH |
| Storage temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) |
| Water resistant | IP54 (Platform), IP64 (Remote) |
| Weight | Platform with battery ~7 lbs (3190 g) Remote with battery 0.49 lbs (220 g) |
Value-packed compact Clamp Meter with True RMS scoped for HVAC-R Testing

| Display | 4000 count |
| Backlight | 5 minute duration with auto-off. Blue color. SC260 only |
| Overrange | (OL) or (-OL) is displayed |
| Measurement rate | 3 times per second, nominal |
| Zero | Automatic |
| Operating environment | 32°F to 122°F (0°C to 50°C) at <70% relative humidity |
| Storage temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) |
| Accuracy | Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH |
| Temperature coefficient | 0.1 x (specified accuracy) per °C [0°C to 19°C (32°F to 66°F), 28°C to 50° C(82°F to 122°F)] |
| APO (Auto Power Off) | Approx. 30 minutes |
| Power | 9V, NEDA 1604A, IEC 6LR61 9V alkaline battery |
| Battery life | 200 hours typical alkaline (SC220/SC240); 150 hours typical alkaline (SC260) |
| Low battery indication | Battery icon blinks and “LO.bt” is displayed when the battery voltage drops below the operating level |
| Dimensions | 205.5mm(H) x 67.4mm(W) x 45.1mm(D) |
| Weight | Approx. 265g including battery |
| Altitude | Up to 6562 ft (2000m) |
| Overload protection | 600 VDC or 600VAC rms unless otherwise stated |
| Test leads | Use UL listed test leads that comply to UL61010-031 rated CATIII 600V or above |
| Included | Test leads are gold-plated and have removeable safety caps |

1 Year from Date of Purchase (excludes Consumables such as Filters, Gaskets, Leads, Batteries, Fuses, Sensors, Case etc)
Please operate the instrument following all instructions of the operator's manual to avoid impairing the safety of the product.
Ships within 48 hours · Estimated delivery Jun 23 - Jun 28
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order